Item

Piece

Performance

 Detection method

Use CR to detect   current

  Current conversion ratio  10001

 Threshold current (Itc)

8/20µs

12A (set value 10A±20%) / 120A (set value   100A±20%)

 Maximum count 

 discharge current

Imcw,8/20

8/20µs

50kA

 Maximum discharge 

 resistance current

Imcw,10/350

10/350µs

50kA


Item

Performance

Remark

Internal moment

Automatically set according to PC time

Data setting time

Minimum recording 

interval

1 time/second


Time accuracy

±1 min/month (20)


Counting points

16,000

EEPROM (Non-volatile)

Built-in battery

CR-2032

About 1 year (users can change)

Data setting and 

data collection

PC specific software

Use "HOBOware"


Communication

USB

Dedicated USB cable

(purchased separately)

Protection level 

of peripherals

Outdoor cable IP44


Threshold current 

switch

By detecting the 10A/100A switch on the side of the section 10A on the   left side 100A on the right side